Dual Cycle Valve.

The Omega Dual Cycle valves are permanently installed, electronically actuated sleeve type valves which allow for two cycles (closed, open, closed or open, closed, open)

The onboard electronics require no connection to surface. The valves may be programmed to function upon the expiry of a pre-determined time delay, or alternatively by using Omega “PROLOGUE” pressure recognition technology. In addition, a combination of both the above methods may also be utilised. The valves are typically installed in a wellbore with isolation packers above and below in order to provide zonal control and isolation.

Multiple valves can be deployed in one well with differing programmes. Single or multiple zones may be open or closed allowing a well to be tested, flowed or fractured depending on the application. Use of this technology has been proven to increase the productivity of less productive zones and overall well clean up. This also improves the drainage and overall recovery from the well.

The valves are typically run in the closed position and will open once initiated. Sending a further command to the valve will close the valve again. Each Dual Cycle valve features two independent electronics sections either of which can provide the actuation for the device. The electronics are easily programmed from a laptop computer running “Windows” style software and may be set up at the wellsite.

Contingency exists to open or close the valves at any time utilizing conventional wireline techniques to mechanically shift the valves to the open or closed position.

The Prologue range of valves build on the same field proven technology currently available in products such as the Clean Out Valve, Tracer Deployment Valve, Self-Opening Sandface Valve and Command Activated Sandface Valve.

Click here to view PDF data sheet.

Features

  • Field proven electronics.
  • Delayed function for up to 120 days.
  • Top selective profile for pressure control accessories.
  • Defaults to mechanical sleeve.
  • Utilises existing wireline / intervention procedures when mechanically actuated.
  • Large flow areas.
  • Multiple valves in one well.
  • Inexpensive option to smart well equipment.
  • Sleep mode to extend valve life.
  • Programmable Fail Safe Mode.

 

Applications
  • Delay start up of prolific zones.
  • Isolate laterals to allow staged start up.
  • Flow control in laterals
  • Water shut off after start up.
  • Test individual zones following start up or during start up.
  • DST operations.
  • FRAC operations.

 

Benefits
  • Increased production due to better contribution from minor zones.
  • Increased production from improved recovery.
  • Increased production from subsequent water shut off.
  • No hydraulic lines or cables from surface required to function valve.
  • Opens and closes via a variable command signal from surface.
Clean Out Valve Ortho
Technical Specifications.
Tool Size 4.500" 5.500"
End Connections* 4-1/2" Premium Connection 5-1/2"" Premium Connection
Material*

13% cr / Super 13% cr
or AISI 4140 18-22Rc

13% cr or AISI 4140 18-22Rc
OD* 6.260" max 8.00" max
ID* 2.937" min 4.313" min
Flow Area Through Valve 6.775 in² 14.610 in²
Length 132.00" 153.00"
Tensile Rating 288,000 lbs 397,000 lbs
Compressive Rating 288,000 lbs 318,000lbs
Working Pressure Rating 5,000 psi 5,000 psi
Actuating Force Per 1,000 psi To Open: 7,725 lbs
To Close: 5,682 lbs
To Open: 11,000 lbs
To Close: 7,522 lbs
Temperature Rating* 150°C 150°C

 

*Dependant upon customer requirements.
Other sizes and ratings are available on request.