Pressure Activated Equalising Valve:

PA-EV

The Omega Pressure Activated Equalising Valve (PA-EV) allows plugged wells to be equalised or brought on to production without the requirement of intervention.

Unlike mechanical devices which require multiple cycles or overpressure, the onboard electronics monitor ambient pressure and pressure changes for a control signal. This signal can be modified at the wellsite prior to running. Recognition of the signal results in tool opening regardless of overbalance or underbalance.

Alternatively, the tool may be programmed to open on a specific date and time without any signal. The PA-EV may be utilised in a suspended well and opened many months after installation. It also has applications when running sub sea completions as a temporary barrier. Installed below a lock, bridge plug or packer.

With very few parts and a rugged design, no special consideration need be given to storage, handling or operation of the device.

Click here to view PDF data sheet.

Features

  • Large flow ports for maximum flow bypass.
  • Standard Field Proven Omega Electronics.
  • Compatible with any Locks & Bridge Plugs.
  • Short overall length.

 

Applications
  • Rapid resumption of production without well intervention.
  • Remote equalisation when intervention access is limited.
  • Shallow set barrier for tree testing/maintenance & change out.
  • Deep set barrier for packer setting and tubing testing.
  • Isolation and opening of Multi Lateral Legs.
  • Reducing slickline runs in retrieving plug assemblies.

 

Benefits
  • Reduces intervention cost’s.
  • Minimizes wireline runs.
  • Controlled equalisation.
  • No risk during under balance equalisation.
Technical Specifications.
Tool Size 3.500" 2.500"
End Connections Blanked to suit Lock / Bridge Plug Blanked to suit Lock / Bridge Plug
Material 41/40 or Customer Specified 41/40 or Customer Specified
OD 3.346 Max 2.50" Max
Flow Area 3.144² 1.606²
Length 33.15" 34.72"
Pressure Rating 10,000 psi 10,000 psi
Max Operating Temperature 150ºC 150ºC
Operating Window Any pressure between 750 psi and 10,000 psi applied for any time between 10 mins and 10 hours. Fully adjustable. Any pressure between 750 psi and 10,000 psi applied for any time between 10 mins and 10 hours. Fully adjustable.
Test Criteria ISO/14310-V3 ISO/14310-V3

 

Other sizes can be manufactured on request.